Classe100 V16M Video internal unit
with handset
Legend
Side view
Configuration
Door Status Function
The device must be only physically configured.
N - Internal unit number
The configurators inserted in the N socket of the internal unit assign a system
identification number. The internal units must be configured in progressive order.
Internal units with parallel connection (max 3 inside apartments without item 346850)
must be configured using the same N configurator. In parallel additional audio and video
internal units may be installed.
P – Entrance panel association
The configurators connected to the P socket of the internal unit assign the associated EP,
the first entrance panel that switches on with the auto-switching on pushbutton and
which door lock is activated when pressing the door lock pushbutton while the internal
unit is idle.
This function indicates the status of the door lock: when open, the “door lock LED”
flashes, when closed, it’s off (only for systems with door locks or actuators intended for
this function).
Configurator socket
Safe door lock
It allows the opening of the door lock only if the entrance panel
and the internal unit are communicating. Connect the JMP*
configurator to activate the function.
Note: this function does not allow the operation of the door
lock pushbutton when idle, or the “Favorites” key (only if M =
1) when idle.
NN
Internal unit address.
PP
Entrance panel address with activation in idle condition and
direct auto-switching ON.
M
Operating modes:
Mod 0 = Staircase Light Activation.
Mod 1 = direct entrance panel door lock opening (configured
with P+1) without call, or activation of the actuator
item 346210 (configured with P+1 and MOD=5),
or activation of door lock actuator item 346230
(configured with P+1).
Mod 2 = Automatic activation of the EP (configured with
P+1) camera, directly without call, or activation of
the actuator item 346210 (configured with P+1 and
MOD=9).
Mod 3 = Intercom among internal units; it sends calls to internal
units configured with the same address.
Mod 4 = General intercom. It sends a call to all the internal units
of the system.
Mod 5 = Intercom among configured internal units N=1 N=2.
N=1 sends a call to N=2.
§N=2 sends a call to N=1.
Mod 6 = Predefined intercom.
“Preset intercom” function with intercom call to the
Internal Unit configured with N=1. It is possible to
send an intercom call from the system Internal units to
the internal unit configured with N= 1.
The internal unit configured with N=1 receives
Intercom calls but cannot send them.
* Note: the JMP configurator (item 3501/JMP) in not supplied.
6.
Volume adjustment and bell exclusion
7.
Image brightness adjustment
8.
Image colour adjustment
9.
ON/OFF micro-switch for the closure of the line at the last internal unit of the riser
or leg.
Switch to ON if the device is the last of the riser or leg
10.
BUS connection clamp
11.
Call to the floor pushbutton
12.
Configurator socket
13.
“Master/Slave” selector