background image

1

www.bticino.com

03/06/2019

ST-00000471-

2

3

4

5

A

B

C

200 mm

200 mm

21 mm

B

A

C

344625

EN

Legend

Note

: When pressed, keys 3/4/5 light up and emit a “beep” that cannot be disabled

1. 

Display

2. 

Call exclusion/device status LED*

3. 

Auto-switching on/Scrolling key 
Direct entrance panel activation (without call) / Cycling / Call to the switchboard (if 
applicable)

4. 

Door lock release pushbutton** 
Direct door lock activation or activation of the door lock of the active entrance 
panel.

5. 

“Favourites” pushbutton (see M configuration mode)

Front view

2 WIRE video internal unit, with handset, for surface installation. It has a 4.3” (16:9) 
colour display. Available pushbuttons: auto-switching on, door lock release, staircase 
light control/various actuators. Depending on the configurator inserted in (M), the same 
pushbuttons will perform different functions (see the specific configuration section). 
LEDs for: call exclusion, communication with entrance panel. Side adjustment for: 
display colour and brightness as well as call exclusion/volume (16 different selectable 
tones). The surface installation must be made with the supplied metal base.

Description

Dimensional data

Classe100 V16M Video internal unit  

with handset

BUS/SCS consumption:  

18 – 27Vdc

Consumption at rest:  

10 mA

Max. operating absorption:  

200 mA

Operating temperature:  

5 – 40°C

Technical data

* Notification by means of two-colour LED of the operating status

Red LED ON steady

bell exclusion

Red LED ON flashing

call bell selection

Green LED ON steady

communication in progress

Green LED ON flashing 

incoming call

** Notification by means of white LED of the door status

LED ON flashing 

door open

LED OFF

door closed

Summary of Contents for 344625

Page 1: ...USER MANUAL BTICINO DOOR ENTRY SYSTEM CLASSE 100 VIDEO DOORPHONE WITH HANDSET 344625 V16M 2020 D10000823A 16 11 2022...

Page 2: ...segnala lo stato della serratura se aperta il pulsante serratura lampeggia se chiusa rimane spento solo se il sistema dotato di serratura o attuatore destinati a questa funzione 1 Display 2 Red LED st...

Page 3: ...ly if the entrance panel and the internal unit are communicating Connect the JMP configurator to activate the function Note this function does not allow the operation of the door lock pushbu tton when...

Page 4: ...Selezione suoneria di chiamata al piano Floor call bell selection Selezione suoneria di chiamata intercomunicante Intercom call bell selection 1 3 2 2 2 Riagganciare per confermare la selezione o atte...

Page 5: ...sa dei cavi rispettando le normative vigenti Collegare i cavi di alimentazione secondo le indicazioni Per eventuali espansioni di impianto utilizzare solo gli articoli indicati nelle specifiche tecnic...

Page 6: ...iousactuators Dependingontheconfiguratorinsertedin M thesame pushbuttons will perform different functions see the specific configuration section LEDs for call exclusion communication with entrance pan...

Page 7: ...rites key only if M 1 when idle NN Internal unit address PP Entrance panel address with activation in idle condition and direct auto switching ON M Operating modes Mod 0 Staircase Light Activation Mod...

Page 8: ...onfigured with S 1 S 2 S 3 are configured as default and cannot be changed Call bell selection Note if no action is performed during call ringtone selection mode for more than 20 the device returns to...

Page 9: ...Web https elkesan fi https elkesan fi d1000883 https elkesan fi d10000822 K ytt ohje User manual D10000823A 16 11 2022...

Reviews: