BWS Series Indicator Technical Manual
- 10 -
•
Check mode
ng
:
When the weight is out of the limits, the beeper will be
sounded and OK will show.
Note: Check weighing available only when weight more than 20d
5.3. Accumulation
The scale can be set to accumulate manually by pressing
key. For settings,
see the parameter
p 1 Com
»
mode
»
pr 2
Before operation scale should be stable and returned to zero, accumulation
available only when weight is more than 20d.
Accumulation Operation
•
Place the load on the platform.
•
Press
key, when STABLE is displayed on the screen.
•
Display will be show
acc 1
then
will show the total saved value. These
displays will only be shown for three seconds.
•
Remove the weight from the platform.
•
When display get zeroed and stable then place the second weight on the
platform.
•
This will continue until the memory gets full or 99 items.
5.3.1 Memory Recall:
To recall the memory press
key.
Display will be show
acc
X
(X: Total number of accumulations)
then
will show
the total saved value. These displays will be shown for only three seconds.
5.3.2. Memory Clear:
To clear the memory, press
and
keys together.
Display will show
Acc 0
, all accumulation memory will be cleared.