BWS Series Indicator Technical Manual
- 22 -
10. ERROR CODES
Error Message
Description
Solution
-----
-----
-----
-----
Maximum load exceeded
Unload or reduce weight.
Err L
Err L
Err L
Err L
Low reading
Re-check wiring
Err 4
Err 4
Err 4
Err 4
Zero setting error
Zero setting range exceeded
due to switching on.(4%max)
Make sure platform is empty.
Err 5
Err 5
Err 5
Err 5
Key board error
Check the keys and connecter.
Err 6
Err 6
Err 6
Err 6
A/D value out of range
Make sure platform is empty.
Check the load cell connectors.
Err 9
Err 9
Err 9
Err 9
Unstable Reading
Check any air variation,
vibration, RF noise and
binding somewhere.
Check the load cell and
connecters.
Err 1
Err 1
Err 1
Err 1 7777
Tare out of range
Remove the load and restart
scale again.
--ol--
--ol--
--ol--
--ol--
Over range
Remove the load.
Recalibrate
fAIL H
fAIL H
fAIL H
fAIL H
faIL L
faIL L
faIL L
faIL L
Calibration Error
Recalibrate
Err p
Err p
Err p
Err p
Printer error
Check the printer and settings.
flashing backlight Battery low
Recharge battery, check the
voltages.
Ba
Ba
Ba
Ba LO
LO
LO
LO
LO ba
LO ba
LO ba
LO ba
Battery low
Recharge battery, check the
voltages.