BT603 Users Manual
12.2.
Continuity
Test
The tester calculates the wire resistance like normal multimeters; therefore, the cable has to form a loop, e.g. the far end of the cable has
to be shorted. The maximum measurable resistance is 50 K
Ω
.
③
④
④
⑤
①
②
①
②
Figure 33 Continuity Test
①
Measured resistance. If this does not exceed 150
Ω
, then a buzzer sound is generated so that the continuity of the cable is
confirmed.
②
Connector used for testing. To change the connector, press
or
; then the test is conducted on ‘BNC’
→
‘1-2 (RJ45)’
→
‘3-6
(RJ45)’
→
‘4-5 (RJ45)’
→
‘7-8 (RJ45)’
→
‘BNC’.
③
To stop the test, press
. (The measured value just before is displayed in
①.)
④
To go back to the previous menu, press
or
.
⑤
To run the test again, press
. (Continuity mode runs continuously to help you measure resistance.)
41