![BST BT603 User Manual Download Page 11](http://html1.mh-extra.com/html/bst/bt603/bt603_user-manual_2823674011.webp)
BT603 Users Manual
6
4. Connecting
Cables
Before connecting cables, be sure to check the following:
1.
Power sources (over 6.5 volts) should not be connected to the far end of the cable.
2.
Cable must be connected to only one of the two connectors: BNC connector (
②
in Figure 2
) or RJ45 connector (
③
in Figure 2).
Depending on the cable you want to connect, you can use:
Coaxial Cable
Connect it directly to the BNC connector.
Shielded Twisted Pair
(STP) Cable
Connect it directly to the RJ45 connector.
Unshielded Twisted Pair
(UTP) Cable
Connect it directly to the RJ45 connector.
Unshielded Multi-Core
Cable
After connecting the alligator clip lead to the
BNC connector; choose one pair of the cable
using the alligator clips.
The tester is not intended to be connected to active systems, or equipment. Prolonged exposure to the voltages applied by these
interfaces may damage the tester.
If the tester detects voltage over 6.5V, a “WARNING” screen is displayed. Disconnect the tester if the voltage warning symbol appears.