- 69 -
PS-8810
DIGITAL SIGNAL PROCESSOR
Ambient Level Meter
Indicates the calculated ambient level for the automix group.
Group Gate Threshold Ambient Offset
Sets the amount above the calculated ambient level for the gate
threshold for all inputs participating in the automix group.
•
For inputs with ambient weighting factors equal to zero or
one, the actual gate threshold will be offset from the
calculated ambient level by this amount.
•
For inputs with ambient weighting factors between zero and
one, the offset is expanded prior to adding it to the
calculated ambient level - the smaller the weighting factor,
the larger the expansion.
Control range is from 0 to 20dB in 0.5dB steps
Individual Control:
Ambience Weighting
The weighting factor used in the ambient level calculation for
each input. This control should be set to 1 with the following
two exceptions:
1.
To exclude the mic from the ambient level calculation,
set the weighting factor to zero
2.
To compensate for a mic in a relatively noisy location
set the weighting factor to a value between zero and one.
Control range is from 0 to 1 in 0.1 step increments.
9
.
/
Processing Functions
Auto-Mixer
Summary of Contents for Prosys PS-8810
Page 1: ...PS 8810 Digital Signal Processor Connect here first User Manual ...
Page 12: ... 12 PS 8810 DIGITAL SIGNAL PROCESSOR ...
Page 16: ... 16 PS 8810 DIGITAL SIGNAL PROCESSOR Controls Connectors Indicators ...
Page 88: ... 88 PS 8810 DIGITAL SIGNAL PROCESSOR CobraNet ...
Page 96: ... 96 PS 8810 DIGITAL SIGNAL PROCESSOR External Control ...
Page 102: ... 102 PS 8810 DIGITAL SIGNAL PROCESSOR PS8810 IR Code Format ...
Page 111: ... 111 PS 8810 DIGITAL SIGNAL PROCESSOR Reference Section ...
Page 116: ... 116 PS 8810 DIGITAL SIGNAL PROCESSOR 19 0 Block Diagram ...
Page 120: ... 120 PS 8810 DIGITAL SIGNAL PROCESSOR 21 0 User Notes ...
Page 121: ... 121 PS 8810 DIGITAL SIGNAL PROCESSOR User Notes ...