INTRODUCTION
27
2
Slave Node Alarms:
A l
e r
t
:
I D
- N E T
N o d e # X X
F a
i
l
# Y Y Y
X = slave node number (1-31)
Y = numeric error value
Reading Results:
A A A A
X X X X X X X X X X X
Y Y C o d e s
A = reading result – Good (Good Read), Part (Partial Read), Mult (Multiple Read)
X = code content
Y = number of codes read
G o o d
X X X X X X X X X X X
Y Y
D G T
D
W W W
S S S
X = code content
Y = number of digits in the code
DGT = "digits"
D = code direction – F=forward, R=reverse, U=unknown
Linear Reading (only if the Quality Counters parameter is enabled)
W = number of scans on the code
S = Quality Counters value (max 100)
Code Reconstruction
W = number of scans on the code (max 255)
S = number of decodes (max 255), on the digit in the code which was decoded the least