RAPID CONFIGURATION
5
1
DS4800 OM Models
1. To mount the DS4800 OM, use the mounting bracket to obtain the most suitable position
for the reader as shown in the figures below.
Figure 6 - Positioning with Mounting Bracket
2. When mounting the DS4800 OM take into consideration these three ideal label position
angles:
Skew 15° to 30°, Tilt 0° and Pitch 0°
. The Skew angle refers to the most inclined
or external raster line, so that all other raster lines assure
more
than 15° Skew.
Assure at least 15°
Minimize
Minimize
Figure 7 –Skew, Tilt and Pitch Angles
3. Refer to the Reading Diagrams in par. 7.4.2 to decide the distance your scanner should
be positioned at.
S
T
P
Tilt
Skew
0° 15° 45°
-45°
-15°
alignment marks