Fault diagnosis
2016-03-10 / DIS 184_58300000140186_ara_en_k
Copyright by BSH Hausgeräte GmbH
Page 52 of 181
Fault
Possible cause
Troubleshooting
Water escapes into the cooking
compartment via the steam inlet
The electronics is not receiving a signal
from the level sensor of the steam genera-
tor.
► Check that the connection between the steam generator’s level sensor and the
electronics
is in place
.
► Check that the connection between the steam generator’s level sensor and the
electronics is
not interrupted
.
► Check whether the connection between the steam generator’s level sensor and the
electronics is
plugged in
.
► Check that the connection between the steam generator’s level sensor and the
electronics is
plugged in correctly
(K141 / X76.1 - it is possible to plug the level
sensor into the edge connector two pins to one side).
Remove water tank
is displayed when the
pyrolytic self-clean system is started
(The error memory reports F5211 al-
though the water tank has been re-
moved)
The water tank level sensor is incorrectly
calibrated.
-
A calibrated water tank level sensor cannot be calibrated afresh.
► Replace the water tank level sensor.
Fill water tank
is displayed although the
tank is still full
The electronics are not receiving a signal
from the level sensor of the steam genera-
tor.
► Check that the connection between the steam generator’s level sensor and the
electronics
is in place
.
► Check that the connection between the steam generator’s level sensor and the
electronics is
not interrupted
.
► Check whether the connection between the steam generator’s level sensor and the
electronics is
plugged in
.
► Check that the connection between the steam generator's level sensor and the
electronics is
plugged in correctly
(K141/X76.1 - it is possible to plug the level
sensor into the edge connector 2 pins further to one side).