Test
2017-03-23 / DIS 184_58300000197442_ARA_EN_A
Copyright by BSH Hausgeräte GmbH
Page 77 of 101
8. Launch the component test program K37 and check the mechanical function of
the vapour extraction system.
Result:
The eccentric makes one full rotation and travels from the 90° position (flap
slightly open) to the 180° position (flap 28° open).
9. Switch off the appliance.
10. Switch on the appliance.
11. Set the operating mode
hot air eco
.
12.
Depending on the operating mode, the flap may remain in
the same position until the cooling fan switches on (at about
80 °C).
When the cooling fan switches on, the motor rotates the
eccentric to 0° (vapour valve closed).
Measure the microswitch (closer): S28.1 - S28.2
Result:
0 Ω = 0° position