Design and function
2017-03-23 / DIS 184_58300000197442_ARA_EN_A
Copyright by BSH Hausgeräte GmbH
Page 18 of 101
For hot air:
•
-
Accuracy: The appliance switches back to the operating mode from which
the rapid heat-up function was started before the temperature reaches its
target value
-
Peak heat: As for hot air, this may be slightly higher for temperatures
<150 °C
-
Heating element: Top heat outer circuit ~90 % plus ring heating element
•
Special features and characteristics:
-
Temporary operating mode, not independent.
For conventional operating modes:
•
-
Accuracy: The appliance switches back to the operating mode from which
the rapid heat-up function was started before the temperature reaches its
target value
-
Peak heat: As for conventional operation modes, this may be slightly higher
for temperatures <150 °C
-
Heating element: Bottom heating and ring heating element
•
Special features and characteristics:
-
Temporary operating mode, not independent
-
On reaching 75 % of the selected target temperature the appliance
switches from settings 1 to settings 2 (type of element control and
circulated air motor)
3.5.11
coolStart
•
-
Accuracy: ±10 K
-
Peak heat: Considerable temperature overshoot < 20 K - 30 K
-
Heating element: Bottom heating and ring heating element, subsequently
ring heating element
•
Special features and characteristics:
-
On reaching 90 % of the selected target temperature the appliance
switches from settings 1 to settings 2 (type of element control and
circulated air motor)