Mounting Evolution Control

First, become familiar with all plastic assembly pieces shown in
Figs 3 through 6. The User Interface will snap together with the

backplate.

Deluxe

 

User Interface

® 

A09432

Fig. 3 -- Evolution

t

Control

A backplate is supplied (see Fig. 4). Attach backplate using only a

small hole in the wall allowing a four wire connection to pass
through. Mount the assembly to the backplate.

D  S1 

S2 

A09441

Fig. 4 -- Backplate

NOTE

: Once Evolution Control is secured to wall with the

backplate assembly (snapped together), care must be taken not to
bend or break the interlocking tabs when removing.

Decorative Backplate

Sold separately, a thin decorative backplate (see Fig. 5) is available
to hide any marks/screw holes left from the previous thermostat.

This decorative backplate (or beauty ring) is used by snapping it
onto the back of the mounting plate before securing the plate to the

wall.

A04017

Fig. 5 -- Decorative Backplate

Deluxe

 

User Interface

® 

A09434

Fig. 6 -- Decorative Backplate Assembly

INSTALLING EVOLUTION CONTROL

Removing Evolution Control

To remove the control from the base, insert a flat screw driver into

each of the four slots (two on each side) and pry towards yourself

to release the holding tabs. Refer to Fig. 7 to locate the slots.

A10076

Fig. 7 -- Slot Locations

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury,

death or equipment damage.
Before installing, modifying, or servicing system, the main

electrical disconnect switch must be in the OFF position.

There may be more than 1 disconnect switch. Lock out and

tag switch with a suitable warning label.

!

WARNING

1. Turn off all power to equipment.
2. If an existing User Interface or control is being replaced:

a. Remove existing control from wall.

b. Disconnect wires from existing control.

c. Discard or recycle old control.

NOTE

: Mercury is a hazardous waste, if existing control contains

any mercury, it MUST be disposed of properly. The User Interface
does not contain mercury.

3. Select Evolution Control mounting plastic (recess mount or

surface mount and decorative backplate if desired).

4. Route wires through large hole in mounting plastic. Level

rear plastic against wall (for aesthetic value only -- Evolu-

tion Control need not be level to operate properly) and mark
wall through two mounting holes.

UID

01

--

D

Summary of Contents for SYSTXBBUID01--D

Page 1: ...tential for personal injury Understand the signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in sev...

Page 2: ...S In areas with poor air circulation such as behind a door or in an alcove Remote Room Sensor Option A Remote Room Sensor can be used with the Evolution Control to take the place of the User Interface...

Page 3: ...To remove the control from the base insert a flat screw driver into each of the four slots two on each side and pry towards yourself to release the holding tabs Refer to Fig 7 to locate the slots A100...

Page 4: ...ABCD connector will cause the Evolution System to operate improperly Check to make sure all wiring is correct before proceeding with installation or turning on power CAUTION 9 Push any excess wire int...

Page 5: ...5 Fig 13 Power Up Sequence NOTE If the variable speed indoor equipment furnace or fan coil cannot be found the User Interface will display CANNOT COMMUNICATE WITH INDOOR UNIT This MUST be corrected be...

Page 6: ...ress right side button to continue UV Lights Installed This screen will appear to select whether UV lights are installed on the system select YES or NO then press right side button to continue Equipme...

Page 7: ...g temperature using the RIGHT Up Down button 7 Press the blue COOL button Cooling temperature will be gin flashing 8 Set the cooling temperature using the RIGHT Up Down button 9 Set the remaining peri...

Page 8: ...ttings S Yes No to reset the user settings in the Advanced Setup to factory default settings Install Settings S Yes No to reset install settings in Install Service menus to factory default settings La...

Page 9: ...supply products e g fresh air make up air dampers S FAN SPEED select Low Med High for all zones when G terminal is energized S SHUTDOWN shuts off fan and equipment when initiated This function is not...

Page 10: ...alue limited by the model number of the fan coil If the electric heater is self identifying this value is not shown Elect Heat Lockout S NONE default S 5 to 55_F 15 to 13_C Outside temperature above w...

Page 11: ...e settings YES NO HP TO FURNACE STAGING TIME Adjust the minimum amount of time the heat pump will run before furnace will be allowed to run S Default 15 MIN S Available settings 15 60 minutes If a dem...

Page 12: ...own in Fig 28 CHECKOUT FURNACE HEAT PUMP HEATING HEAT PUMP COOLING HUMIDIFIER VENTILATOR BACK SELECT A03204 Fig 28 Checkout Menu Checkout Furnace or Gas PAC Make sure the furnace is properly installed...

Page 13: ...S Seconds If a lockout timer is active this will show the current time value See furnace manual for details on lockout timers Service Fan Coil Status Electric Heat S OFF LOW MED HIGH Displays stages...

Page 14: ...he same time for 3 seconds When keys are locked a lock symbol will appear in the upper left corner of screen Follow same procedure to unlock keypad Heat and Cool LED The Heat and Cool LEDs will pulsat...

Page 15: ...ings ON and OFF If DEHUMIDIFY is set to ON factory default then the cooling unit will be allowed to overcool the space up to 3_F 2_C if the humidity level is above the cooling humidity target setpoint...

Page 16: ...ectly to indoor unit with a short piece of thermostat wire Add other devices one at a time to determine where the communication issue exists Display says Outdoor Unit Not Found and I have a two stage...

Page 17: ...e over as the system controller putting the regular system user interface to sleep The screen on the regular user interface will display IN SERVICE MODE The D model user interface will then learn all...

Page 18: ...hange at any time specifications or designs without notice and without incurring obligations E2011 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in China Edition Date 0...

Reviews: