—2—
DIMENSIONS (IN.)
UNIT
SIZE
SERIES
A
B
C
D
E
F
G
H
K
L
M
N
MINIMUM MOUNTING
PAD DIMENSIONS
024
B
33-13/16 22-1/2
26-3/16
4-1/8
7-1/8
21-15/16 28-3/8
5/8
12
13-3/4
12
2-3/8
20 x 27
036
B
27-13/16
30
33
5-1/16
9-11/16 15-15/16 22-3/8
3/4
16-1/4
14
13-1/8
2-15/16
26 x 32
048
B
39-13/16
30
33
5-1/16
9-11/16 27-15/16 34-3/8
7/8
16-1/4
14-1/4
14-1/2
2-15/16
26 x 32
060
C
39-13/16
30
33
5-1/16
9-11/16 27-15/16 34-3/8
7/8
16
13-3/4
15-3/4
2-15/16
26 x 32
AIR DISCHARGE
AIR DISCHARGE
AIR IN
AIR IN
AIR IN
3
/
8
"
DIA. TIEDOWN KNOCKOUTS
(2) PLACES
L
K
N
E
D
C
L
ACCESS
PANEL
1
1
/
4
"
2
1
/
2
"
AIR DISCHARGE
1
3
/
4
"
4
3
/
16
"
3/8" DIA. LIQUID
LINE CONN.
H
DIA. VAPOR
LINE CONN.
7/8" DIA. HOLE
FIELD POWER SUPPLY CONN.
7
/
8
"
DIA.
HOLE WITH 1
1
/
8
"
DIA. KNOCKOUT
AND 1
3
/
8
"
DIA. KNOCKOUT
10
1
/
2
"
FIELD CONTROL
SUPPLY CONN
1
9
/
16
"
C
F
8
3
/
16
"
G
A
B
M
NOTES:
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55
°
F, MAX. 125
°
F.
3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66
°
F.
4. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER.
5. CENTER OF GRAVITY .
A03061
COMPRESSOR PROTECTION
—The compressor is protected
with an internal overload. An internal pressure relief valve pro-
vides high-pressure protection to the refrigerant system.
EXTERNAL SERVICE VALVES
—Both service valves are brass,
back seating type with sweat connections. Valves are externally
located so refrigerant connections can be made quickly and eas-
ily. Each valve has a service port for ease of checking operating
refrigerant pressures.
EASY SERVICEABILITY
—Removal of access panel and con-
trol box cover provides easy access to the compressor and all
electrical controls. Removal of top provides access to fan motor
and coil. A self-diagnostic indicator on the electronic control
board informs the service technician of the failed component.
STANDARD FEATURES
—An electronic control eliminates
excessive wiring. A compressor sound hood and discharge muf-
fler provide improved sound levels as well as sound quality.
COMPRESSOR START ASSIST
—Capacitor and relay is
factory-supplied.
THERMOSTATIC EXPANSION VALVE
—This unit must be
installed with a Puron-refrigerant TXV on the indoor coil. The FV4
indoor fan coils and CK5P indoor furnace coils are factory
equipped with a bi-flow, balanced port Puron-refrigerant TXV.
When installed in this application, no further change is required. If
any other indoor fan coil or furnace coil is used, a balanced-port
Puron-refrigerant TXV must be installed. See accessory list in this
publication for part number for your application. The 037 size only
is factory equipped with a Puron-refrigerant, hard shutoff bal-
anced-port TXV.
LIMITED WARRANTY
—Five-year warranty on all parts with a
10-year warranty on the compressor. Refer to warranty certifi-
cate for specific details.
DIMENSIONS
MODEL NUMBER NOMENCLATURE
698B
N
X
024
Model No.
17 SEER
Two-Speed
Heat Pump
Electrical Supply
N
— 208/230-1-60
N/A
Nominal Cooling Capacity
024 –
2 ton
036
– 3 ton
048
– 4 ton
060
– 5 ton
000
A
A
AA
Standard Unit
Series
A — Original Series
B — Second Series
Common Unit—
U.S.A. Only
Heating Size