HEAT PUMP HEATING PERFORMANCE continued
See notes on page 56.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
698BNX024-B Outdoor Section With FV4BNF002 Indoor Section - Low Speed continued
65
400
4.91
4.47
0.73
6.78
6.02
0.79
8.78
7.99
0.85
10.88
10.88
0.90
13.08
13.08
0.95
15.46
15.46
1.00
500
5.15
4.70
0.74
7.09
6.30
0.79
9.19
8.36
0.84
11.35
11.35
0.88
13.68
13.68
0.91
16.19
16.19
0.95
600
5.34
4.87
0.74
7.32
6.51
0.79
9.47
8.62
0.83
11.68
11.68
0.86
14.05
14.05
0.89
16.63
16.63
0.92
700
5.48
4.99
0.74
7.52
6.68
0.79
9.69
8.82
0.82
11.92
11.92
0.85
14.32
14.32
0.88
16.92
16.92
0.90
800
5.58
5.09
0.75
7.65
6.80
0.79
9.85
8.96
0.82
12.11
12.11
0.85
14.50
14.50
0.87
17.10
17.10
0.89
70
400
4.39
4.00
0.74
6.28
5.58
0.80
8.29
7.54
0.86
10.41
10.41
0.92
12.59
12.59
0.98
14.96
14.96
1.04
500
4.63
4.22
0.74
6.61
5.87
0.80
8.70
7.91
0.86
10.88
10.88
0.90
13.19
13.19
0.95
15.70
15.70
1.00
600
4.80
4.38
0.75
6.83
6.07
0.80
8.97
8.16
0.85
11.21
11.21
0.89
13.59
13.59
0.93
16.15
16.15
0.96
700
4.93
4.50
0.75
6.98
6.20
0.80
9.18
8.36
0.85
11.45
11.45
0.88
13.85
13.85
0.91
16.45
16.45
0.95
800
4.98
4.54
0.76
7.14
6.34
0.81
9.35
8.51
0.85
11.63
11.63
0.88
14.05
14.05
0.91
16.63
16.63
0.94
75
400
3.82
3.49
0.75
5.77
5.12
0.81
7.79
7.09
0.88
9.94
9.94
0.95
12.13
12.13
1.01
14.47
14.47
1.07
500
4.00
3.65
0.75
6.07
5.39
0.81
8.18
7.44
0.87
10.41
10.41
0.93
12.68
12.68
0.98
15.16
15.16
1.03
600
4.19
3.82
0.76
6.30
5.59
0.82
8.46
7.70
0.87
10.74
10.74
0.92
13.08
13.08
0.96
15.53
15.53
1.00
700
4.36
3.98
0.76
6.46
5.74
0.82
8.67
7.89
0.87
10.97
10.97
0.92
13.36
13.36
0.95
15.96
15.96
0.99
800
4.46
4.07
0.76
6.59
5.86
0.82
8.83
8.04
0.87
11.15
11.15
0.91
13.57
13.57
0.94
16.17
16.17
0.98
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Low Speed
Indoor
Section
Size
Low Speed
Capacity
Power
Capacity
Power
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CK5PW
024
1.02
1.01
CC5A/CD5AA
024
1.00
1.04
030
1.02
1.02
030
1.00
1.03
036
1.04
1.01
036
1.00
0.99
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AW
024
1.00
1.04
CC5A/CD5AA
036
1.02
1.01
030
1.00
1.03
CC5A/CD5AW
024
1.00
1.03
036
1.02
1.01
030
1.00
1.02
CE3AA
024
1.02
1.04
036
1.02
1.01
030
1.02
1.03
CE3AA
024
1.02
1.04
036
1.02
1.02
030
1.02
1.02
CK3BA
024
1.02
1.01
036
1.02
1.02
030
1.02
1.01
CK3BA
024
1.02
1.01
036
1.04
1.01
030
1.02
1.01
CK5A/CK5BA
024
1.02
1.01
036
1.04
1.01
030
1.02
1.02
CK5A/CK5BA
036
1.04
1.01
036
1.04
1.01
CK5A/CK5BT
036
1.04
1.01
CK5A/CK5BT
036
1.04
1.01
CK5A/CK5BW
024
1.04
1.03
CK5A/CK5BW
024
1.02
1.01
030
1.02
1.01
030
1.02
1.02
036
1.04
1.01
036
1.04
1.01
CK5PA
036
1.04
1.01
CK5PA
024
1.02
1.01
CK5PT
036
1.04
1.01
030
1.02
1.02
CK5PW
024
1.04
1.03
036
1.04
1.01
030
1.02
1.01
CK5PT
036
1.04
1.01
036
1.04
1.01