—54—
HEAT PUMP HEATING PERFORMANCE continued
See notes on page 56.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
Total
Int*
kW‡
698BNX048-B Outdoor Section With FV4BNF005 Indoor Section - Low Speed continued
65
850
13.14
11.98
1.53
16.54
14.69
1.64
20.48
18.64
1.77
24.67
24.67
1.91
29.26
29.26
2.06
34.43
34.43
2.26
1075
13.57
12.37
1.53
17.14
15.22
1.64
21.06
19.17
1.76
25.31
25.31
1.90
29.94
29.94
2.05
35.36
35.36
2.21
1300
13.88
12.65
1.55
17.50
15.54
1.65
21.42
19.49
1.77
25.66
25.66
1.91
30.25
30.25
2.06
35.45
35.45
2.20
1525
14.15
12.90
1.57
17.76
15.78
1.67
21.65
19.70
1.79
25.86
25.86
1.93
30.63
30.63
2.07
35.81
35.81
2.23
1750
14.35
13.08
1.59
17.97
15.96
1.69
21.82
19.85
1.81
26.02
26.02
1.95
30.85
30.85
2.08
35.89
35.89
2.24
70
850
12.53
11.43
1.56
15.93
14.15
1.68
19.74
17.96
1.81
23.91
23.91
1.95
28.50
28.50
2.12
33.58
33.58
2.32
1075
12.97
11.83
1.57
16.49
14.65
1.68
20.34
18.51
1.80
24.57
24.57
1.94
29.19
29.19
2.10
34.08
34.08
2.26
1300
13.26
12.09
1.58
16.88
14.99
1.69
20.80
18.93
1.82
24.93
24.93
1.95
29.54
29.54
2.11
34.87
34.87
2.27
1525
13.53
12.34
1.60
17.14
15.22
1.71
21.04
19.15
1.84
25.18
25.18
1.97
29.75
29.75
2.14
35.14
35.14
2.28
1750
13.75
12.54
1.62
17.35
15.41
1.73
21.20
19.29
1.86
25.35
25.35
2.00
30.00
30.00
2.14
35.00
35.00
2.30
75
850
11.91
10.86
1.60
15.32
13.60
1.72
19.05
17.34
1.86
23.19
23.19
2.01
27.70
27.70
2.17
32.70
32.70
2.37
1075
12.34
11.25
1.60
15.83
14.06
1.72
19.63
17.86
1.84
23.89
23.89
2.00
28.42
28.42
2.16
33.47
33.47
2.35
1300
12.66
11.54
1.62
16.20
14.39
1.73
20.03
18.23
1.85
24.25
24.25
2.00
28.78
28.78
2.17
34.02
34.02
2.33
1525
12.91
11.77
1.64
16.49
14.65
1.75
20.29
18.46
1.87
24.43
24.43
2.01
29.01
29.01
2.18
34.19
34.19
2.33
1750
13.10
11.94
1.66
16.71
14.84
1.76
20.53
18.68
1.89
24.69
24.69
2.04
29.17
29.17
2.21
34.31
34.31
2.35
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Low Speed
Indoor
Section
Size
Low Speed
Capacity
Power
Capacity
Power
CE3AA
048
1.00
1.04
CC5A/CD5AC
048
1.00
1.11
060
1.00
1.02
CC5A/CD5AW
048
1.00
1.08
CK3BA
048
1.00
1.02
CD5AA
048
1.00
1.07
060
1.00
0.99
CE3AA
048
1.00
1.07
CK5A/CK5BA
048
1.00
1.02
060
1.00
1.05
060
1.00
0.99
CK3BA
048
1.00
1.05
CK5A/CK5BT
048
1.00
1.02
060
1.00
1.02
060
1.00
0.99
CK5A/CK5BA
048
1.00
1.05
CK5A/CK5BW
048
1.00
1.02
060
1.00
1.02
CK5A/CK5BX
060
1.00
0.99
CK5A/CK5BT
048
1.00
1.05
CK5PA
048
1.00
1.02
060
1.00
1.02
060
1.00
0.99
CK5A/CK5BW
048
1.00
1.05
CK5PT
048
1.00
1.02
CK5PA
048
1.00
1.05
060
1.00
0.99
060
1.00
1.02
CK5PW
048
1.00
1.02
CK5PT
048
1.00
1.05
CK5PX
060
1.00
0.99
060
1.00
1.02
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK5PW
048
1.00
1.05
CC5A/CD5AA
060
1.00
1.09
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AC
048
1.00
1.12
CC5A/CD5AA
060
1.00
1.09
CC5A/CD5AW
048
1.00
1.08
CC5A/CD5AC
048
1.00
1.11
CD5AA
048
1.00
1.08
CC5A/CD5AW
048
1.00
1.08
CE3AA
048
1.00
1.07
CD5AA
048
1.00
1.08
060
1.00
1.06
CE3AA
048
1.00
1.07
CK3BA
048
1.00
1.06
060
1.00
1.05
060
1.00
1.03
CK3BA
048
1.00
1.05
CK5A/CK5BA
048
1.00
1.06
060
1.00
1.02
060
1.00
1.02
CK5A/CK5BA
048
1.00
1.05
CK5A/CK5BT
048
1.00
1.06
060
1.00
1.02
060
1.00
1.02
CK5A/CK5BT
048
1.00
1.05
CK5A/CK5BW
048
1.00
1.05
060
1.00
1.02
CK5PA
048
1.00
1.06
CK5A/CK5BW
048
1.00
1.05
060
1.00
1.02
CK5PA
048
1.00
1.05
CK5PT
048
1.00
1.06
060
1.00
1.02
060
1.00
1.02
CK5PT
048
1.00
1.05
CK5PW
048
1.00
1.05
060
1.00
1.02
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK5PW
048
1.00
1.05
CC5A/CD5AA
060
1.00
1.09
—
—
—
Summary of Contents for 698B
Page 58: ... 58 ...