CLEANUP AND START-UP INSTRUCTIONS
1. Start furnace using procedure outlined on Lighting Instruc-
tions attached to furnace. Observe operation of furnace
through at least 1 complete heating cycle controlled from
room thermostat. Observe cycle for 20 minutes or until a
status code is flashed. If status code flashes, refer to Index.
2. Recycle as necessary and check thermostat heat anticipator
setting, gas input rates, and temperature rises. These proce-
dures are outlined in Installation, Start-Up, and Operating
Instructions.
3. Check operation of safety devices: draft safeguard switch,
limit switch, and flame rollout switch(es).
4. Put all setup switches in their proper positions. On variable-
speed units, put EZ-SELECT airflow control jumpers in
their proper positions.
5. Remove tape from door switch.
6. Replace thermostat leads (if necessary).
7. Set thermostat in AUTO position, calling for heat.
8. Set thermostat to desired temperature.
9. Replace blower and control doors. Clean up.
—28—