Seite 7 von 11
Recommended BDC-settings for a test assembly
Recommended BDC-settings for operation
“fuel cell to battery”:
BDC_1:
UHS_COM_1 > 170V
ILS_MAX_1 >
|
ILS_MIN_2
|
ILS_MIN_1 = -2 (prevention of buckmode)
IHS_MAX_1 >
|
IHS_MIN_2
| (
Recommendation: IHS_MAX_1 > ILS_MAX_1)
IHS_MIN_1 = -2 (prevention of buckmode)
BDC_2:
UHS_COM_2 < UHS_COM_1
|
ILS_MIN_2
|
< ILS_MAX1
ILS_MAX_2 = 2 (prevention of boostmode)
|
IHS_MIN_2
|
< IHS_MAX_1
(
Recommendation: |IHS_MIN_2| > |ILS_MIN_2|)
IHS_MAX_2 = 2 (prevention of boostmode)
HS- and LS-voltage limit regulators have to be set according to the fuel cell and battery specifications.
BDC546
ILS_MIN active
UHS_MAX [SG_UHS_max]
IHS_MAX
[SG_IHS_max]
IHS_MIN [SG_IHS_min]
ULS_MAX [SG_ULS_max]
ILS_MAX [SG_ILS_max]
ILS_MIN [SG_ILS_min]
ULS_MIN [SG_ULS_min]
High-Side (HS)
Low-Side (LS)
UHS_MIN [SG_UHS_min]
BDC546
UHS_COM active
ULS_MAX [SG_ULS_max]
ILS_MAX [SG_ILS_max]
ILS_MIN [SG_ILS_min]
UHS_MAX [SG_UHS_max]
IHS_MAX [SG_IHS_max]
IHS_MIN [SG_IHS_min]
UHS_MIN [SG_UHS_min]
High-Side (HS)
Low-Side (LS)
ULS_MIN
[SG_ULS_min]
Fuel Cell
Battery
BDC_1
UHS_COM [SG_Sollwert]
UHS_COM [SG_Sollwert]
BDC_2
ULS1
UHS
ULS2