Seite 5 von 11
UHS-main-regulator
The main-regulator regulates the high-side-voltage. For a functional operation, the following CAN-messages
have to be set correctly:
[SG_Sollwert]:
Value of the commanded high-side voltage.
(Sollwert
engl.: desired value)
[SG_HR_Mode_Check]:
0x1
Interpretation of the internal current measurement
Boostmode
Direction of current from LS to HS.
Current measurements have a positive value.
[BDC_ILS_act] & [BDC_IHS_act] > 0
Responsible current-limit-regulators:
IHS_MAX
[SG_IHS_max] > 0
ILS_MAX
[SG_ILS_max] > 0
Buckmode
Direction of current from HS to LS.
Current measurements have a negative value.
[BDC_ILS_act] & [BDC_IHS_act] < 0
Responsible current-limit-regulators:
IHS_MIN
[SG_IHS_min] < 0
ILS_MIN
[SG_ILS_min] < 0
With the current-limit-regulators, the user can avoid an unexpected change of the mode. (Boostmode to
buckmode or buckmode to boostmode.)
Limit regulators
On reaching one or more set limit-values, the device will regulate on this values under compliance of the
regulator-priority. The device won
’t switch off.