Introduction
This document has to be read before startup the device first time. Otherwise damage on the device and
external connected devices can occur.
The signal names in squared brackets (
[ ]
) are the references to the CAN-matrix.
List of abbreviations
U:
Voltage
I:
Current
HS:
High-Side
LS:
Low-Side
LIM:
Limit
MAX: Maximum
MIN:
Minimum
REG: Regulator
COM: Commanded
Valid regulator-values
ULS_MIN:
0V
(CAN-error is set, if the value is out of the range.)
ULS_MAX:
600V
(CAN-error is set, if the value is out of the range.)
UHS_MIN:
0V
(CAN-error is set, if the value is out of the range.)
UHS_MAX:
750V
(CAN-error is set, if the value is out of the range.)
ILS_MIN:
0 to -400A
(CAN-error is set, if the value is out of the range.)
ILS_MAX:
0 to 400A
(CAN-error is set, if the value is out of the range.)
IHS_MIN:
0 to -400A
(CAN-error is set, if the value is out of the range.)
IHS_MAX:
0 to 400A
(CAN-error is set, if the value is out of the range.)
UHS_COM:
0 to 1024V
(0 to -1024V)
(The device doesn’t check this value. If the UHS_COM
value is higher than UHS_MAX or lower than UHS_MIN, the device
is going to regulate on the limiting-values.)