![Bruno ELECTRA-RIDE LT Manual Download Page 26](http://html1.mh-extra.com/html/bruno/electra-ride-lt/electra-ride-lt_manual_2821178026.webp)
©2011,2005 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-2750 INSTALL 05-17-2011
26
TESTING THE CALL/SEND TRANSMITTER
1. Using the rocker switch on the seat armrest, run
the unit up and down the rail.
NOTE: The unit should travel noticeably
faster going upthan down.
2. Check for smooth operation and travel.
3. Now, using one of the remote call/send transmitters,
run the unit up and down the rail.
4. Repeat Step 3 with the other transmitter.
5. Check for smooth operation and travel.
Soft Start Feature
The controller includes a
soft
start
feature which causes a
short delay
between the time the
rocker switch on the armrest is
depressed and the initiation of
carriage movement.
This is normal!
ELECTRICAL
CIRCUIT BOARD DIAGNOSTICS
The circuit board provided on the SRE-2750 is equipped with (4) diagnostic modes that continuously
monitor the unit’s operation. This choice of operational modes allows the SRE-2750 to respond to the
requirements of a wide variety of installations.
NOTE : The SRE-2750 is shipped in the MULTI-USER/DIAGNOSTIC MODE.
MULTI-USER/DIAGNOSTIC MODE
Provides full range of Audio diagnostic notices:
*
Circuit Board Power Up
: Chirp
*
Safety Device Activated
: Chirp
*
Elevator Stopped Off Charge Bumper
: 5 Beeps (4 short and 1 long)
Repeats every 3 minutes until the Elevator is returned to the bumper.
*
Seat Safety Disengaged
: Chirp repeats every 3 seconds until seat safety switch is re-engaged.
*
Battery Voltage Drop
: 5 Beeps (3 short and 2 long)
Repeats every 4 minutes until seat safety switch is disengaged, the battery voltage increases, or
the switch is pressed.
*
Battery Voltage Critical
: 5 Beeps (2 short and 3 long)
Repeats once a minute until the voltage exceeds 16V or the switch is pressed.
*
Switch Active During Power Up
: 2 Beeps / Pause / 5 Beeps (long beeps indicate which
switches are active)
Repeats beeps every 5 seconds until all switches are off.
*
More Than One Switch Active
: 2 Beeps / Pause / 5 Beeps (long beeps indicate which switches
are active)
Repeats every 30 seconds until all switches are off.
*
Transmitter ID Memory Full
: 3 Beeps (1 short and 2 long)
SINGLE-USER MODE
Provides the same audio diagnostic notices as the Multi-User/Diagnostic Mode, except for the Seat
Safety Disengaged notice.
QUIET MODE
In the QUIET mode, none of the Audible Warning Messages is active.
BATTERY WARNINGS ONLY MODE
Provides battery audio diagnostic only.
*
Elevator Stopped Off Charge Bumper
: 5 Beeps (4 short and 1 long)
Repeats every 3 minutes until Elevator is returned to the bumper.
*
Battery Voltage Drop
: 5 Beeps (3 short and 2 long)
Repeats once every 4 minutes until the seat safety switch is disengaged or the battery voltage
increases.
*
Battery Voltage Critical
: 5 Beeps (2 short and 3 long)
Repeats once a minute until voltage is above 16 V.