BRUGG Rohrsysteme GmbH ·- Adolf-Oesterheld-Str. 31 - D-31515 Wunstorf
Tel.: +49 (0) 5031 170-0 Fax: +49 (0) 5031 170-170 e-mail: [email protected]
page 7 of 11
Key functions:
ON/OFF
Used to switch the machine on and off
0..9
Numeric keys to enter joint and building-site-specific data
A
Display of measured values
E
Enter – confirmation of inputs
C
Clear – changing of defined values and deletion of error messages
OK
Confirmation of defined values
R
Return – switches within the queries one query back or within the input
of joint-specific values one point back
START
Starts the welding process
Sequence
Action Display No./Remarks
ON key
CAW04 V1.0
1. The machine carries out a RESET and
checks the power supply and internal
temperature.
CAW04 V1.0
2. The machine is ready. If a weld pool sensor
<Date> <Time>
is connected, the temperature can be
queried by pressing the A key.
OK
PIN old:000
3. Query of the operator's PIN number. The
PIN new:___
inputs can only be confirmed with E when
all the digits required have been entered
completely, e.g. the PIN no. 1 must be
entered as 001.
PIN old:000
PIN new:001
4. Confirm input with E.
Proj. no. old:0000
Proj. no. new:____
5. Input of the project number (four-digit).
Confirm with E after input of the last digit,
e.g.: 1234.
Joint no.:
6. Input of the joint number (four-digit),
e.g.: 5678.
DN old: 0000
DN new:____
7. Input of the nominal diameter (four-digit),
e.g.: 0315.