After a certain welding time the weld pool temperature has not risen to the extent
expected. It is possible that a temperature sensor not belonging to the welding
section has been connected.
5
Spare-parts catalog
Fine-wire fuse (6.3 x 32 mm, 16A/250V)
delayed-action
Available in retail shops
Thermal cable (TK01, 4 m long)
Stock no. 83100191
Connection cable (AK01, 2 m long)
Stock no. 83100192
Welding cable set (SK01, set of 2, each 4 m)
Stock no. 83100193
Data transmission line (2 m long)
Stock no. 83100194
6
Maintenance
The welding machine must be sent in annually for maintenance to BRUGG.
7
Transport and storage
The unit must be stored in a warm, dry area. Protect the unit against shock while in
transport, e.g. non-slip foam-rubber pad. The machine must be properly secured at
all times during transport (tension belts).
8
Decommissioning
The welding machine must be returned to BRUGG for proper decommissioning.