CHAPTER 4
Introduction to Hardware
49
Table 4.1
Types and modules comprising PULSE front-ends (shaded cells are Dyn-X modules)
Type
Product Name
Frequency
Range
Aux. Channels
Simultaneous
Channels
Connec-
tors
Input Type
Type 3560-B
3560-B-010
5-channel
PULSE Data
Acquisition Unit
0 Hz to
25.6 kHz
16 Aux Input
d
(10 samples/s)
2 Digital Output
5 Input
1 Sine Output
LEMO
Direct/CCLD
a, b
/Mic. Preamp.
1 Tacho Conditioning
c
3560-B-110
3560-B-020
BNC
Direct/CCLD
a
1 Tacho Conditioning
c
3560-B-120
3560-B-030
5 Input
1 Generator
Output
LEMO
Direct/CCLD
a, b
/Mic. Preamp.
1 Tacho Conditioning
c
3560-B-130
3560-B-040
BNC
Direct/CCLD
a
1 Tacho Conditioning
c
3560-B-140
Types 3560-C, D, E
C D E
3109
Generator,
4/2-ch. Input/
Output Module
0 Hz to
25.6 kHz
–
4 Input
2 Generator
Output
LEMO
and
BNC
Direct/CCLD
a
/Mic. Preamp.
1 Tacho Conditioning
c
1
of
t
hese modul
es, up t
o
17 inpu
t chann
els
Up to 5 of
th
ese
mo
dule
s,
up to
6
5
i
nput
ch
anne
ls
Up to 8 of
th
ese
mo
dule
s,
up to
9
6
i
nput
ch
anne
ls
3110
Generator,
2/1-ch. Input/
Output Module
0 Hz to
204.8 kHz
2 Input
1 Generator
Output
e
3038
12-ch. Input
Module
0 Hz to
25.6 kHz
12 Input
BNC
Direct/CCLD
a
2 Tacho Conditioning
c
3040
3038-B
2
×
Sub-D Direct/CCLD
a
/Mic. Preamp.
b
3040-B
3039
6-ch. Input
Module
6 Input
BNC
Direct/CCLD
a
/Mic. Preamp
1 Tacho Conditioning
c
3041
3039-B
Sub-D
Direct/CCLD
a
/Mic. Preamp.
b
3041-B
3035
6-ch. Charge &
CCLD Input
Module
0 Hz to
25.6 kHz
–
6 Input
BNT/
BNC
and TNC
Charge/Direct/CCLD
a
Tacho Conditioning on BNT
Connector
UA-1365
Blank Module
–
7536
Controller
Module
–
16 Aux Input
d
(10 samples/s)
2 Digital Output
–
1 of
th
ese
mo
dule
s
1 of
th
ese
mo
dule
s
1 of
th
ese
mo
dule
s
7537
5/1-ch.
Input/Output
Controller
Module
0 Hz to
25.6 kHz
5 Input
1 Sine Output
LEMO
Direct/CCLD
a, b
/Mic. Preamp.
1 Tacho Conditioning
c
7538
7539
5 Input
1 Generator
Output
7540
7537-A
5 Input
1 Sine Output
BNC
Direct/CCLD
a
1 Tacho Conditioning
c
7538-A
7539-A
5 Input
1 Generator
Output
7540-A
a.
Constant Current Line Drive for DeltaTron
®
and ICP
®
Accelerometers or Microphone Preamplifier
b.
Using adaptor cables
c.
All input channels can be used for tachometer operation
d.
Only 12 channels currently supported in PULSE software
e.
Upper frequency @ 102.4 kHz
Summary of Contents for PULSE 3560-B
Page 2: ......
Page 8: ......
Page 11: ...Part I Installation...
Page 12: ......
Page 44: ...PULSE Multi analyzer System Type 3560 B C D E Installation and IDAe Hardware 36...
Page 53: ...Part II Hardware...
Page 54: ......
Page 110: ...PULSE Multi analyzer System Type 3560 B C D E Installation and IDAe Hardware 102...
Page 140: ...PULSE Multi analyzer System Type 3560 B C D E Installation and IDAe Hardware 132...
Page 142: ...PULSE Multi analyzer System Type 3560 B C D E Installation and IDAe Hardware 134...
Page 143: ...Part III Appendices...
Page 144: ......
Page 148: ...PULSE Multi analyzer System Type 3560 B C D E Installation and IDAe Hardware 140...
Page 161: ......