![Brother PT-P900W Software Manual Download Page 79](http://html.mh-extra.com/html/brother/pt-p900w/pt-p900w_software-manual_55156079.webp)
P-touch Template Command Reference
- 73 -
7.
Control Command Details
ESC iXn2 Select template
ASCII:
ESC i
X n
2 n1 n2 n3
Decimal:
27 105 88 110 50 nd1 nd2 nd3
Hexadecimal: 1B 69 58 6E 32 nh1 nh2 nh3
Parameters
nh1: 01h (Fixed)
nh2: 00h (Fixed)
01h
≤
nh3
≤
63h
Description
Specifies the number of the template selected from the machine.
n3: Template number (1 to 99)
The default selection number is 1.
This command is a static command.
Remarks
The template numbers that can be set are between 1 and 99.
This command becomes invalid if any other value has been specified or if the number that has been
specified is of a template not transferred to the machine.
Example
To select template number 99:
Since nh3=63h, the command will be as follows.
ESC i X n 2 01h 00h 63h
(1Bh 69h 58h 6Eh 32h 01h 00h 63h)