P-touch Template Command Reference
- 99 -
7.
Control Command Details
ESC iXm1 Retrieve character code set setting
ASCII:
ESC i
X m
1 n1 n2
Decimal:
27 105 88 109 49 nd1 nd2
Hexadecimal: 1B 69 58 6D 31 nh1 nh2
Parameters
nh1: 00h (Fixed)
nh2: 00h (Fixed)
Description
Retrieves the specified character code set.
(For details on the character code sets, refer to “
Appendix B: Character Code Tables
”.)
3-byte data is returned from the printer.
[1]: 01h (Fixed)
[2]: 00h (Fixed)
[3]: Setting
00h: Brother standard
01h: Windows1250 (Eastern Europe)
02h: Windows1252 (Western Europe)
The retrieved value is a value specified by a static command.
Example
When the character code set is the Brother standard:
Code: ESC i X m 1 00h 00h
(1Bh 69h 58h 6Dh 31h 00h 00h)