![Brother PT-P900W Software Manual Download Page 53](http://html.mh-extra.com/html/brother/pt-p900w/pt-p900w_software-manual_55156053.webp)
P-touch Template Command Reference
- 47 -
7.
Control Command Details
^QV
Specify QR Code version
ASCII:
^
Q V n1 n2
Decimal:
94 81 86 nd1 nd2
Hexadecimal: 5E 51 56 nh1 nh2
Parameters
0
≤
n1
≤
4
0
≤
n2
≤
9
Description
Specifies the QR code version.
(n1*10)
+
n2: Version number (between 0 and 40)
The default QR Code version is 0.
This command becomes invalid if a value other than those that can be set (between 0 and 40) has been
specified.
This command is a dynamic command.
If the print range is exceeded, the bar code is not printed.
Example
To change the version to 10:
Since n1=1 and n2=0, the command will be as follows.
^ Q V 1 0
(5Eh 51h 56h 31h 30h)