Control Command Details
ESC iXr2 Specify print start received character count
ASCII:
ESC i
X r
2 n1 n2 n3 n4
Decimal:
27 105 88 114 50 nd1 nd2 nd3 nd4
Hexadecimal: 1B 69 58 72 32 nh1 nh2 nh3 nh4
Parameters
nh1: 02h (Fixed)
nh2: 00h (Fixed)
00h
≤
nh3
≤
FFh
00h
≤
nh4
≤
03h
Description
Specifies the number of characters to be received in order to start printing.
nh3+(nh4*256): Print start received character count (bytes) (1 to 999)
The default print start received character count is 10.
This command is a static command.
Example
To change the print start received character count to 100 characters:
Since nh3=64h and nh4=00h, the command will be as follows.
ESC i X r 2 02h 00h 64h 00h