VI –
7
(3) Compatibility [checking the NSF and DIS]
Code 1
Code 2
Causes
32
01
Remote terminal only with V.29 capability in 2400 or 4800
bps transmission.
32
02
Remote terminal not ready for polling.
32
10
Remote terminal not equipped with password function or
its password switch OFF.
32
11
Remote terminal not equipped with or not ready for confi-
dential mail box function.
32
12
Remote terminal not equipped with or not ready for relay
broadcasting function.
32
13
No confidential mail in the remote terminal.
32
14
The available memory space of the remote terminal is less
than that required for reception of the confidential or relay
broadcasting instruction.