V –
18
WSW06
(PAUSE key setting and 2nd dial tone detection)
Function
Selector
No.
Setting and Specifications
PAUSE key setting and 2nd dial
tone detection
2nd dial tone interrupt detecting
time
1
|
3
4
|
6
8
7
No. of dial tone detection times
0:
Once
1:
Twice
0:
30 ms
1:
50 ms
Detection of international tone
No. 1
2
3
0
0
0
:
No pause
0
0
1
:
3.5 sec. WAIT
0
1
0
:
7 sec. WAIT
0
1
1
:
10.5 sec. WAIT
1
0
0
:
14 sec. WAIT
1
0
1
:
17.5 sec. WAIT
1
1
0
:
2nd dial tone detection
only in pulse dialing
(DP) system
1
1
1
:
2nd dial tone detection
both in DP and push-
button (PB) dialing
systems
No. 4
5
6
0
0
0
:
50 ms
0
0
1
:
210 ms
0
1
0
:
500 ms
0
1
1
:
800 ms
1
0
0
:
900 ms
1
0
1
:
1.5 sec.
1
1
0
:
2.0 sec.
1
1
1
:
2.5 sec.
NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection
is supported, e.g., U.S.A.
●
Selectors 1 through 3:
PAUSE key setting and 2nd dial tone detection
Selectors
1
2
3
0
0
0
No WAIT is inserted even if the PAUSE key is pressed.
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
Pressing the PAUSE key inserts WAIT in pulse dialing, as defined in
the above table.
If the PAUSE key is pressed repeatedly, the equipment beeps a refusal
sound and refuses the entry.
In hook-up dialing, however, the equipment allows repeated pressing
with an acceptance sound, but inserts WAIT only for the first pressing.
1
1
0
1
1
1
Each time the PAUSE key is pressed, the equipment detects a 2nd
dial tone.
If no 2nd dial tone is inputted within the specified time, the equipment
disconnects the line in automatic dialing, or it starts transmitting the
dial signal if given after depression of the PAUSE key in hook-up
dialing.
(In those countries where no dial tone detection function is supported,
setting these selectors to "1, 1, 0" or "1, 1, 1" inserts a WAIT of 3.5
seconds.)
Summary of Contents for MFC 1870MC
Page 4: ...CHAPTER I GENERAL DESCRIPTION ...
Page 10: ...CHAPTER II INSTALLATION ...
Page 11: ...CHAPTER III THEORY OF OPERATION ...
Page 43: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 94: ...CHAPTER V MAINTENANCE MODE ...
Page 101: ...V 6 Scanning Compensation Data List MFC1970MC Scanning Compensation Data List Other models ...
Page 148: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Page 191: ...D Power Supply 100 120V U S A CANADA TAIWAN ...
Page 192: ...D Power Supply 200 240V EUROPE SOUTH AMERICA ...
Page 193: ...D Power Supply 200 240V GULF ASIA CHINA ...
Page 197: ......
Page 203: ......
Page 206: ......