Circuit board DIP switch 2
No.
ON/OFF
Setting items
Default
ON
Pedal: for standing operation
1
OFF
Pedal: for seated operation
OFF
ON
Starting possible only when work clamp is lowered
2
OFF
Starting possible regardless of work clamp position
OFF
ON
During standing pedal operation, the work clamp lowers only
while the work clamp pedal is being depressed.
3
OFF
During standing pedal operation, the work clamp keeps
lowering when the work clamp pedal is released.
OFF
ON
-
4
OFF
-
OFF
ON
-
5
OFF
-
OFF
ON
100V, 110V specifications
6
OFF
200V, 220V, 230V, 380V, 400V specifications
ON/OFF
ON
-
7
OFF
-
OFF
ON
-
8
OFF
-
OFF
Note:
Move the switches properly.