6. ELECTRIC COMPONENTS AND SOFTWARE
HE-800A
127
6-4-2. Signal names for connectors and probable symptoms due to poor contact
1. Circuit board connectors [Main circuit board]
P1 [FAN2]
Pin no.
Signal name
Probable symptoms due to poor contact
1
+24V
2
FAN2 signal
3
0V
• The inside air circulation fan does not operate.
• Error E-41 is displayed.
P3 [SYNC]
Pin no.
Signal name
Probable symptoms due to poor contact
1
+5V
2
Encoder signal
3
Needle up stop position signal
4
Needle down stop position signal
5
0V
• The machine motor does not turn.
• A machine stopping error occurs.
• One of error E-02, E-62, E-63 and E-64 is displayed.
P4 [PANEL]
Pin no.
Signal name
Probable symptoms due to poor contact
1
+5V
2
0V
3
KEY0
4
KEY1
5
KEY2
6
OC
7
A
8
B
9
C
10
D
11
E
12
F
13
G
14
STB
15
P8V
16
SENSOR
17
BUZZER
18
0V
19
0V
20
0V
• The operation panel does not operate.