6. ELECTRIC COMPONENTS AND SOFTWARE
HE-800A
128
P6 [POWER]
Pin no.
Signal name
Probable symptoms due to poor contact
1
P8V (+8V)
2
0V
3
N8V (-8V)
4
OV. det
5
RY. out
6
OV. FAULT
7
+5V
8
PHOTO
9
U
10
V
11
W
12
U
13
V
14
W
15
IPM. FAULT
• The power indicator of operation panel does not illuminate.
• The machine motor does not turn.
P7 [PEDAL]
Pin no.
Signal name
Probable symptoms due to poor contact
1
P8V (+8V)
2
PEDAL signal
3
0V
4
N8V (-8V)
• The home position can not be found.
• Work clamp does not operate.
• The machine does not operate.
• One of error E-30, E-31 and E-32 is displayed.
P9 [HPEDAL] Standing operation pedal (option)
Pin no.
Signal name
Probable symptoms due to poor contact
1
P8V (+8V)
2
Work clamp (FORSW) signal
3
Backward (BAKSW) signal
4
0V
5
Spare (INCHSW) signal
6
Start (PRSW) signal
7
Spare (HPEDAL) signal
• The home position can not be found.
• Work clamp does not operate.
• The machine does not operate.
• One of error E-30, E-31 and E-32 is displayed.
P10 [HEAD]
Pin no.
Signal name
Probable symptoms due to poor contact
1
Stop NC signal
2
0V
3
Stop NO signal
4
+24V
5
-
6
0V
7
+5V
8
Thread breakage detection signal
9
-
10
P8V (+8V)
11
0V
• The stop switch is not activated.
• The thread breakage detection does not operate normally.