App. 4-41
Confidential
WSW38
(V.34 transmission settings)
Selector
No.
Function
Setting and Specifications
1
2
Setting of the equalizer
No. 1
2
0
X
:
Automatic
1
0
:
Fixed to 4 points
1
1
:
Fixed to 16 points
3
Sending level of guard tone at phase
2
0: Normal - 7 db
1: Normal
4
Stepping down the transmission
speed at fallback each
0: 2400 bps
1: 4800 bps
5
6
Automatic control of modem's
EQM gain for proper transmission
speed choice
No. 5
6
0
0
:
For higher transmission speed
than the current setting
0
1
:
No change from the current
setting
1
0
:
For lower transmission speed
than the current setting
1
1
:
For further lower transmission
than the setting made by 1, 0
7
Redialing when a communications
error occurs
0: ON
1:
OFF
8
Detection of CED for stopping
CNG
0: ON
1:
OFF
NOTE:
WSW38 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in models
supporting V.34 mode.
l
Selectors 1 and 2: Setting of the equalizer
These selectors set the equalizer's training level to be applied if the machine fails to send training due
to weak line connection. If these selectors are set to "0, X," the modem will automatically set the
appropriate training level.
l
Selector 3:
Sending level of guard tone at phase 2
This selector sets the sending level of guard tone for 1800 Hz to be sent at Phase 2 in the V. 34 mode.
l
Selector 4:
Stepping down the transmission speed at fallback each
This selector determines how much the modem steps down the transmission speed at fallback when
called by the remote station. If this selector is set to "1," the modem may step down the transmission
speed from 33600 bps to 28800 bps by one-time fallback.
l
Selectors 5 and 6: Automatic control of modem's EQM gain for proper transmission speed choice
These selectors determine how the modem controls the EQM (Eye Quality Monitor) gain for proper
choice of the transmission speed, which applies if the modem selects higher transmission speed than
the possible speed so that it always repeats falling back.
l
Selector 8:
Detection of CED for stopping CNG
If this selector is set to "0," the detection time of CED specified by WSW43, selectors 4 and 5 will
apply.
Summary of Contents for FAX 1840C
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC3340CN 3240C FAX1940CN 1840C 1835C ...
Page 9: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 18: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 50: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 91: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 167: ...5 69 Confidential Viewed from the left ...
Page 171: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 191: ...6 18 Confidential Vertical Alignment Check Patterns ...
Page 193: ...6 20 Confidential Margin Check Pattern ...
Page 202: ...Confidential CHAPTER 7 CLEANING ...
Page 205: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 216: ...8 9 Confidential Scanning Compensation Data List a b c d e f i ...
Page 236: ...8 29 Confidential 1st sheet 2nd sheet Vertical Alignment Check Patterns ...
Page 239: ...8 32 Confidential Margin Check Pattern ...
Page 249: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 253: ...9 2 Confidential ...
Page 254: ...9 3 Confidential ...
Page 371: ...B Power Supply PCB U S A and Canadian models Confidential ...
Page 372: ...B Power Supply PCB European and Asian models Confidential ...
Page 401: ...Confidential February 05 SM FAX032 8XA901 5 Printed in Japan ...