2-120
Confidential
Completely blank
All black
Vertical streaks
<User Check>
• Check that the document is not reversed.
Step
Cause
Remedy
1
Incorrect white level correction data Execute "Acquire white level data (
)".
2
First or second side CIS flat cable
failure
Replace the first or second side CIS flat
cable.
3
First or second side CIS unit failure Replace the first or second side CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Install all the latest firmwares.
Step
Cause
Remedy
1
Incorrect white level correction data Execute "Acquire white level data (
)".
2
First or second side CIS flat cable
failure
Replace the first or second side CIS flat
cable.
3
First or second side CIS unit failure Replace the first or second side CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Clean the scanner glass or first side/second side
scanner glass strip.
• Clean the document hold.
Step
Cause
Remedy
1
Dirt inside of scanner glass
Clean the inside of the scanner glass.
2
Dirt inside of first side/second side
scanner glass strip
Clean the inside of the first side/second side
scanner glass strip.
3
First or second side CIS unit failure Replace the first or second side CIS unit.
4
Scratch on scanner glass
Replace the document scanner unit.
5
Scratch on second side scanner
glass strip
Replace the ADF unit.