4.6.2 Nothing is displayed on the LED
4.6.3 Control panel is inoperable
<User Check>
• Turn the power switch OFF and then ON again.
Step
Cause
Remedy
1
Connection failure of the key PCB
flat cable
Reconnect the key PCB flat cable.
2
Panel PCB failure
Replace the panel PCB ASSY.
3
Key PCB failure
Replace the panel unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Turn the power switch OFF and then ON again.
Step
Cause
Remedy
1
Connection failure of the panel flat
cable
Reconnect the panel flat cable.
2
Panel PCB failure
Replace the panel PCB ASSY.
3
Touch panel failure
Replace the touch panel ASSY.
4
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
5
Key PCB failure
Replace the panel unit.
6
Main PCB failure
Replace the main PCB ASSY.