Chapter 1 Preparation of Embroidery Machine
BES-961BC
•
BES-1261BC
25
■
BES-1261BC
r
Bridge
Connecting shaft
Fixing bracket
Fixing bracket B
1.
Remove 3 pieces of fixing screw
q
,loosen 2 pieces of screw
w
and remove the color change
cover
e
.
2.
Remove the bolts
r
and detach the fixing bracket for transportation from the bridge and the
connecting shaft.
3.
Loosen the bolts
t
and move the needle bar case
y
left side.
4.
Press the change bracket collar
i
against the change case base
u
, while pressing the left
side change bracket collar
o
against the change case base
u
, and tighten the bolts
t
.Check
that needle bar No.1 and 12 are inserted into the needle plate holes smoothly.
(Notes)
•
Check that ther is no play for the connecting shaft in the horizontal direction.
•
If the bolt of the right side change bracket collar
i
is loosened, the change bracket collar
i
may be
dislocated and adjusting position of the needle bar case
y
will be required. So don’t loosen this bolt.
5.
Attach the color change cover
e
by 3 pieces of fixing screw
q
and 2 pieces of fixing screw
w
.
u
e
i
w
q
t
o
q
o
y
Summary of Contents for BES-1261BC
Page 7: ...5 BES 961BC BES 1261BC 2 1 7 1 6 3 4 5 7 3 2 Belt cover Finger guard BES 961BC ...
Page 13: ...11 BES 961BC BES 1261BC Setting of thread breakage sensor page 93 Setting of Machine page 96 ...
Page 18: ...16 BES 961BC BES 1261BC ...
Page 19: ...Chapter 1 Preparation of Embroidery Machine ...
Page 60: ...BES 961BC BES 1261BC 58 Chapter 2 Embroidering Procedures ...
Page 78: ...BES 961BC BES 1261BC 76 Chapter 3 Selection of Data and Embroidering ...
Page 118: ...BES 961BC BES 1261BC 116 Chapter 5 Setting ...
Page 119: ...Chapter 6 Operation of Machine ...
Page 130: ...Chapter 6 Operation of Machine BES 961BC BES 1261BC 128 ...
Page 131: ...Chapter 7 Maintenance ...
Page 140: ...Chapter 7 Maintenance BES 961BC BES 1261BC 138 ...
Page 141: ...Chapter 8 Standard Adjustment ...
Page 153: ...Chapter 9 List of Error Messages ...
Page 161: ...Connection and Installation of Optional Equipment ...