13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
51
BE-438C
<Memory switches 30 - 4F>
30 to 4F are set by entering two-digit values.
These values are incremented using the P2 switch, and decremented using the P4 switch.
Switch
Possible setting range
Units
Initial value
Explanation
memo-30
0 - 30
mm
7
Limits the maximum area in the horizontal
direction (X).
(Limited to 6.4 mm when settings have
been initialized.)
memo-31
0 - 30
mm
7
Limits the maximum area in the vertical
direction (Y).
(Limited to 6.4 mm when settings have
been initialized.)
memo-32
12 - 27
×
100rpm
25
Changes the maximum sewing speed.
memo-33
1 - 15
×
7.5
°
10
Changes the feed timing
1(Fast)
←
10 (Standard)
→
15(Slow)
memo-34
0 - 5
Stitch
1
The (setting value + 1) number of stitches
are sewn at the speed set by memo-35 at
the sewing start. (No low-speed sewing if
set to 0.)
memo-35
3 - 9
×
100rpm
4
Changes the sewing start speed for the
number of stitches specified by memo-34
memo-36
−
−
−
−
memo-37
1 - 20
×
7.5
°
10
Changes the feed timing one stitch be-
fore the sewing end.
1(Fast)
←
10 (Standard)
→
20(Slow)
memo-38
1 - 20
×
7.5
°
10
Changes the feed timing two stitches
before the sewing end.
memo-39
1 - 20
×
7.5
°
1
Changes the feed timing for the third
stitch at the sewing start.
1(Fast)
←
10 (Standard)
→
20(Slow)
memo-3A
1 - 20
×
7.5
°
1
Changes the feed timing for the second
stitch at the sewing start.
memo-3b
1 - 20
×
7.5
°
1
Changes the feed timing for the first stitch
at the sewing start.
memo-3c
0 - 99
Stitch
0
Sets the number of stitches for which the
feed timing (memo-33 setting) is enabled.
0: Enabled for all stitches
1 - 99: Enabled for the specified number
of stitches from the sewing start
memo-3d
−
−
−
−
memo-3E
−
−
−
−
memo-3F
−
−
−
−
memo-40
−
−
−
−
memo-41
−
−
−
−
memo-42
0 - 10
−
0
Changes the work clamp operating
mode. (When set to “0”, the mode is
selected according to the settings for DIP
switches A-1 and A-2.)
memo-43
-
memo-4F
−
−
−
−