12. CHANGING FUNCTIONS USING THE DIP SWITCHES
45
BE-438C
12. CHANGING FUNCTIONS USING THE DIP SWITCHES
12-1. Operation panel DIP switches
The functions shown in the table below can be changed by
means of these DIP switches (1).
*
All DIP switches are set to OFF at the time of shipment.
Note:
Always turn off the power before setting the DIP
switches.
Switch
Motion when set to ON
DIPA-1
Presser does not automatically lift after sewing is
completed.
DIPA-2
Two-pedal mode is available.
See “12-2. Setting the presser mode”
DIPA-3
User program mode is available.
DIPA-4
−
DIPA-5
The presser does not rise automatically when a split is found.
DIPA-6
Displays the enlargement/reduction ratio in millimeter units instead of as a percentage. (After
changing this setting, be sure to carry out the auto-clear operation by referring to page 42.)
DIPA-7
Enlargement of pattern size is not available.
DIPA-8
Program number is fixed.
12-2. Setting the presser mode
Through the combination of DIP switches A-1 and A-2 on the operation panel, presser motions can be set as follows:
DIPA-1
DIPA-2
Pedal specifications
Raising the presser at the sewing end
−
−
Single pedal
Presser is raised automatically.
ON
−
Single pedal
Presser is raised by pressing the pedal.
−
ON
Two pedals
Presser is raised automatically, then it is lowered by pressing
the pedal.
ON
ON
Two pedals
Presser is kept lifted while the pedal is pressed.
2586Q