11. OPTIONS
11-2. Upper thread breakage detector assembly ...... (S40520-009)
―
83
―
BAS-705
r
e
u
y
t
q
w
i
o
<
Attachment
>
1. Remove the screw
q
, and then remove the upper cover
w
.
2. Remove the upper cover cap
e
, and then install the thread breakage detector
r
to the upper cover
w
with
the screw
t
and nut
y
.
3. Install the upper cover
w
with the screw
q
.
4. Bind the cord
u
of the thread breakage detector
r
with the band in the same way as the other cords, and
pass it inside the control box.
5. Insert the connector
i
into the 16-pin connector
o
on the main circuit board.
<
When using the upper thread breakage detector assembly
>
●
Set panel DIP switch No. 1-1 to ON and then turn on the power.
<
When not using the upper thread breakage detector assembly
>
●
Set panel DIP switch No. 1-1 to OFF and then turn on the power.
NOTE: Refer to "8. Using the DIP switches" on page 66 for details of the panel DIP switches.