2. FUNCTION SETTINGS
12
BAS-342G
No.
Setting
value
Setting item
Default
value
Thread breakage detector
OFF Disabled
554
ON
Fiber-type upper thread breakage detector is used
OFF
Detection sensitivity for thread breakage detector
OFF
5 stitches at sewing start, 3 stitches while sewing
555
ON
10 stitches at sewing start, 3 stitches while sewing
OFF
Inner clamping device (Option output No. 13)
0 Disabled
1
Inner clamping device is used (Retract operation is carried out at the sewing end
to prevent interference with the needle.)
2
Inner clamping device is used (No retract operation is carried out at the sewing
end)
556
3
Inner clamping device operates for 1/4 of the sewing pattern and returns for the
other 3/4. (No retract operation)
0
External wiper device
0 Disabled
1
Solenoid-type wiper device is used.
557
2
Pneumatic-type wiper device is used. (Option output No. 2)
1
External error monitoring input
OFF Disabled
558
ON
Enabled (P10, option input No. 13 [AIRSW])
OFF
Operating indicator output
OFF Disabled
559
ON
Option output No. 9: Output during operation ON
Option output No. 10: ON during lower thread replacement and during test mode
Option output No. 11: ON when error is generated
OFF
Automatic ejector (Option output No. 3 output, option input No. 1 = right sensor, input No. 2 = left
sensor)
0 Disabled
1
Operates as standard. (*9)
2
Sewing starts when cassette sensor is ON (*9)
560
3
Start switch is enabled even if cassette sensor is OFF. (*9)
0
Timer from sensor detection to sewing start when automatic ejector automatic starting is set
(memory switch No. 560 = 2)
561
0 - 999
Time from after the cassette is chucked until automatic starting
100
Changes the digital tension setting value.
OFF
Tension number can be changed regardless of the sewing data.
562
ON
Only tension No. 0 and the tension numbers detected in the sewing data can be
changed.
ON
2-step thread tension device (when using spring-type main tension)
OFF Disabled
563
ON
2-step thread tension device is used.
OFF
Increases maximum tension release force when using a spring-type main tension
0
Disabled (Thread tension discs are open at the sewing end.)
1
Increase the maximum tension release force (The thread tension discs close at the
sewing end. If the thread tension discs are open, they will be closed for
approximately 5 minutes.)
564
2
Maximum tension release force is set to maximum (The thread tension discs close
at the sewing end. If the thread tension discs are open, they will be closed for
approximately 1 minute.)
0
*9
Set memory switch No. 002 to 0.
Summary of Contents for BAS-342G PS
Page 122: ...8 ELECTRICAL MECHANISM 113 BAS 342G PMD P C board Power supply motor P C board 1260B 4593Q ...
Page 123: ...8 ELECTRICAL MECHANISM 114 BAS 342G Panel P C board 4594Q ...
Page 130: ...8 ELECTRICAL MECHANISM 121 BAS 342G 1424B ...
Page 131: ...8 ELECTRICAL MECHANISM 122 BAS 342G 1425B ...