7. ADJUSTMENT
107
BAS-342G
7-22. Adjusting the needle up stop position
[Adjustment method]
1
TEST indicator and SPEED indicator illuminate.
While pressing the and keys simultaneously, turn
on the power switch.
* Keep pressing the and
keys until the model
name is displayed and the buzzer beeps once.
・
“orG” will flash in the PROGRAM No. display, and the
home position offset value will appear in the menu
display.
2
Lower the work clamp and then depress the start switch.
・
X-Y feed home position detection will be carried out, and then
“orG” will stop flashing and illuminate steadily.
3
Depress the start switch once more.
・
The upper shaft will operate and the needle bar will stop at the
needle up stop position.
4703Q 4448Q 4421Q
1385B
5211Q
Use the operation panel to adjust the needle up stop
position so that the needle bar (1) is lowered 6.2 - 6.7 mm
from its highest position (near the highest stop position for
the thread take-up).
Start switch
Start switch