7. ADJUSTMENT
97
BAS-342G
7-14. Adjusting the work clamp lift amount
The maximum lift amount for the work clamp (2) is 30 mm above the top of the needle plate.
1. Turn on the air, and then turn on the power switch.
2. Depress the work clamp switch (1) to raise the work clamp (2).
3. Loosen the two bolts (4) of the work clamp lifter lever (3), and then move the work clamp lifter lever (3) up or down to adjust
the lift amount.
7-15. Adjusting the air pressure
Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2) downward
to lock it.
4052M
5018Q
Max. 30mm
3975M
Summary of Contents for BAS-342G PS
Page 122: ...8 ELECTRICAL MECHANISM 113 BAS 342G PMD P C board Power supply motor P C board 1260B 4593Q ...
Page 123: ...8 ELECTRICAL MECHANISM 114 BAS 342G Panel P C board 4594Q ...
Page 130: ...8 ELECTRICAL MECHANISM 121 BAS 342G 1424B ...
Page 131: ...8 ELECTRICAL MECHANISM 122 BAS 342G 1425B ...