2. FUNCTION SETTINGS
5
BAS-342G
2-4. List of memory switch settings
Note: Regarding the term “work clamp” in the table
Normally the intermittent presser foot is lifted and dropped at the same time the work clamp is lifted and dropped.
However, the intermittent presser foot can be set not to operate by means of settings such as the setting for memory
switch No. 54.
No.
Setting
value
Setting item
Default
value
Work clamp lift timing after sewing is completed
OFF
Lifts at the final stitch position.
001
ON
Lifts after moving to the sewing start position.
ON
Integrated-type work clamp drop operation
0
Work clamp dropping in 1 step
1
Work clamp dropping in two steps (*1)
002
2
Do not use this setting.
0
Sewing start speed
OFF
The sewing speed for the first 1 to 5 stitches is set by memory switch numbers 151
to 155.
100
ON
1st stitch at 400 rpm, 2nd stitch at 400 rpm, 3rd stitch at 600 rpm, 4th stitch at 900
rpm, 5th stitch at 2,000 rpm
OFF
Single-stitch test feed
OFF
Test feed starts when the start switch is depressed, and it continues automatically
until the final stitch.
200
ON
Test feeding
・
Is carried out one stitch at a time each time the work clamp switch is
depressed
・
Is carried out continuously while the start switch is depressed
・
Is carried out one stitch at a time when the pulley is turned by hand
OFF
Production counter display
OFF
Lower thread counter display
300
ON
Production counter display
OFF
User programs
OFF Disabled
400
ON
User program mode is enabled.
OFF
Cycle programs
OFF Disabled
401
ON
When sewing user programs, the set programs are sewn in numeric order.
OFF
Maximum reduction ratio (mm display) (*2)
OFF
Displayed as %.
402
ON
Displayed as mm.
OFF
Split mode selection
0
Continuous split (split menu is disabled before split detection)
1
Continuous split (split menu is always enabled)
403
2 Independent
split
0
*1
The position of the work clamp stopper must be set. (Refer to the Instruction Manual.)
*2 The mm display may differ slightly from the actual sewing size.