(6) Remove the taptite cup S M3x6 screw, and lift the upper chute earth spring.
(7) Push the two hooks on the upper chute outward, and remove the cover open lever shaft
from the upper chute.
(8) Remove the upper chute earth spring from the upper chute.
(9) Remove the two taptite bind B M3x10 screws, and remove the double feeding sensor
holder from the upper chute.
(10) Release the double feeding sensor harness (Sent) from the securing fixture, and remove
the double feeding sensor (Sent) from the upper chute.
Fig. 3-24
HARNESS ROUTING: Refer to
.
Assembling Note:
• Attach the upper chute earth spring and the cover release lever spring on the position
described in the illustration above.
• Attach the upper chute earth spring under the cover open lever shaft.
Hook
Cover open lever shaft
Upper chute
earth spring
Double feeding sensor holder
Double feeding sensor (Sent)
Hook
Taptite bind B M3x10
Taptite cup S M3x6
Taptite bind B M3x10
Upper chute
Double feeding
sensor harness (Sent)
Cover release lever spring
Earth harness (WH)
Summary of Contents for ADS-2600W
Page 18: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 24: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 30: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 64: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 68: ...3 2 Confidential 2 PACKING ...
Page 110: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 128: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 148: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 150: ...6 1 Confidential 1 WIRING DIAGRAM ...
Page 151: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 152: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 154: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 158: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...