4-6
Confidential
1.6
Setting Double Feeding Sensor Threshold
(1) Connect the machine to your computer using the USB cable in the initial state of
maintenance mode.
(2) Double-click "BrADSmt1.exe" that was saved into the computer to start it.
(3) Select the model name in the [Select model:] box, and click the [Start] button. The
double feeding sensor threshold is reset.
(4) After the following screen is appeared, set the sheet for double feeding sensor threshold
setting in the ADF, and execute the maintenance mode function "Check ADF".
Refer to "1.3.2 ADF performance test (function code: 08)" in Chapter 5.
(5) Execute the maintenance mode function "Acquire white level data and set CIS scan
area".
Refer to "1.3.11 Acquire white level data and set CIS scan area (function code: 55)" in
Chapter 5.
(6) Click the [Yes] button on the screen of step (4). The double feeding sensor threshold is
calculated and stored in the EEPROM of the main PCB.
When the setting is completed normally, "OK" is displayed on the screen.
If any error is detected during setting, "ERROR" is displayed on the screen.
(7) Unplug the AC power cord of the machine.
Summary of Contents for ADS-2600W
Page 18: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 24: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 30: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 64: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 68: ...3 2 Confidential 2 PACKING ...
Page 110: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 128: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 148: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 150: ...6 1 Confidential 1 WIRING DIAGRAM ...
Page 151: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 152: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 154: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 158: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...