Brooks GT1600 Installation And Operation Manual Download Page 9

Section 1

Table 1-2 Capacities - GT1600

cc/min

l/h

ln/h

SLPM

R 2 127 AAAAT

316SS

1.9

0.11

0.11

6.7

R 2 127 AAAAT

CARBOLOY

3.7

0.22

0.2

12

R 2 127 AAT

CARBOLOY

7.5

0.45

0.38

23

R 2 127 DT

316SS

15

0.93

0.68

40

R 2 127 DT

CARBOLOY

25

1.5

1

61

R 2 127 AT

316SS

39

2.3

1.4

86

R 2 127 AT

CARBOLOY

59

3.5

2

120

R 2 127 BT

316SS

110

6.8

3.9

230

R 2 127 BT

CARBOLOY

170

10

5.6

340

R 2 127 CT

CARBOLOY

270

16

9

540

R 6 127 AT

316SS

410

25

14

850

R 6 127 AT

CARBOLOY

620

37

20

1200

R 6 127 BT

316SS

1000

65

35

2100

R 6 127 BT

CARBOLOY

1500

95

49

2900

GPM

l/h

SCFM

m3n/h

7 XV 11A A

0.48

100

1.8

3.1

7 XS 23 A

0.77

170

3.3

5.6

8 XV 8 A

1.00

240

4.4

7.5

8 XV 14 A

1.40

320

5.8

9.9

2.00

460

14

24

9 XS 33 A

3.20

730

13

22

3.90

890

28

48

5.10

1100

36

62

10 XV 64 A

6.20

1400

25

43

10 XS 64 A

7.80

1700

32

54

10.00

2400

80

130

21.00

4800

150

270

7-XV-11A-A

0.41

93

1.8

3.1

7-XS-23-A

0.66

150

2.7

4.6

8-XV-8-A

0.99

220

4

6.9

8-XV-14-A

1.3

310

5.3

9.1

8-XV-31-A*

1.7

400

11

20

9-XS-33-A

3.0

690

12

21

9-XV-87-A*

3.6

830

26

44

9-XS-87-A*

4.5

1000

32

55

10-XV64-A

6

1300

24

41

10-XS-64-A

7.4

1600

30

52

10-XS-138-A*

9.8

2200

68

110

10-XJ-238-A*

20

4700

140

250

8 XV 8 A

0.82

180

3.3

5.6

8 RJ 10

1.5

340

6.3

10

8 RJ 23

2.4

540

9.9

16

8 RJ 30

3.1

710

13

22

8 RJ 39

4.7

1000

10 RJ 80

12

2700

10 RJ 180

21

4900

10 RJ 37

24

40

10 RJ 83

36

62

10 RJ 90

55

93

Note (1) Air flow rates in standard units are at 70°F & 14.7 psia
Note
* These codes require a back pressure of 30 psig / 2bar

(2) Air flow rates in normal units are at 1.013 bar & 20°C

Meter type

127 Low Flow

Size 08

R 8M 75 1

Size 10

R 10M 75 3

075 High Flow

Ring iniator

Tube

Alarm type

Float

Size 02

Size 06

Full scale water

Full scale air

250 High Flow

Size 07

Reed switch

Size 10

Size 09

Size 08

R 7M 25 1FT

R 8M 25 4FT

R 9M 25 3FT

R 10M 25 3FT

127 High Flow

R 7M 127 1F

R 8M 127 4F

R 9M 127 3F

R 10M 127 3F

Size 10

Size 07

Size 08

Size 09

8-XV-31-A*

9-XV-87-A*
9-XS-87-A*

10-XS-138-A*
10-XJ-238-A*

3

 

 

 

 

 

 

 

 

 

 

4

Summary of Contents for GT1600

Page 1: ...Installation and Operation Manual X VA GT1600 eng Part Number 541B220AAG April 2020 GT1600 Series Brooks GT1600 Industrial Glass Tube Variable Area Flowmeter GT1600 Series...

Page 2: ...r electrical and pressure sources Operation 1 Slowly initiate flow into the system Open process valves slowly to avoid flow surges 2 Check for leaks around the flow meter inlet and outlet connections...

Page 3: ...n manual Failure to comply could result in serious personal injury or property damage Protective sleeve must remain over glass tube Meter sizes 7 10 only Fasten meter windows securely Failure to compl...

Page 4: ...lation General 17 Receipt of Equipment 17 Recommended Storage Practice 17 Return Shipment 17 Transit Precautions 18 Installation 18 Section 3 Operation Pre Operational Check 19 Operating Instructions...

Page 5: ...ches for GT1600 Sizes 2 6 15 1 7 Dimensions and Specifications Intrinsically Safe Switch Isolators 16 2 1 Typical Flowmeter Piping Configuration 18 3 1 Typical Flowmeter Piping Configuration 20s 5 1 G...

Page 6: ...peration The operating parts of the flowmeter consist of a tapered glass tube and a float which operates within the tube The fluid enters the bottom of the tube which has the smallest inside diameter...

Page 7: ...ting in the center of the tube The guide ribs do not follow the taper of the tube They are parallel to the tube centerline so that the proper operating clearance for the float is maintained for its en...

Page 8: ...ure Ratings Float wetted Materials of construction Maximum Operating Pressure PSIG bar at Max Operating Temperature Tube size Threaded process connections Flanged process connections Horizontal IN OUT...

Page 9: ...S 23 A 0 66 150 2 7 4 6 8 XV 8 A 0 99 220 4 6 9 8 XV 14 A 1 3 310 5 3 9 1 8 XV 31 A 1 7 400 11 20 9 XS 33 A 3 0 690 12 21 9 XV 87 A 3 6 830 26 44 9 XS 87 A 4 5 1000 32 55 10 XV64 A 6 1300 24 41 10 XS...

Page 10: ...Section 1 Figure 1 4 Dimensions GT1600 Series See Dimensions Tables on following pages 5...

Page 11: ...N H OUT 9 1 4 0 72 120 0 V IN V OUT 1024 19 69 500 0 H IN V OUT 7 8 3 94 100 0 H IN V OUT 9 1 4 0 72 120 0 V IN H OUT 7 3 8 94 100 0 V IN H OUT 9 10 4 72 120 0 H IN H OUT 7 22 88 8 3 50 88 9 H IN H OU...

Page 12: ...H OUT 9 10 15 00 381 0 4 00 101 6 H IN H OUT 9 02 229 1 0 83 21 0 V IN V OUT 11 20 284 6 H IN V OUT 10 11 256 9 0 83 21 0 V IN H OUT 10 11 256 9 0 83 21 0 V IN V OUT Retro t only 4 GT1305 1305 7 75 1...

Page 13: ...v 1 Groups A thru G Ex mb IIC T6 Gb Ex mb IIIC T85 C Db Standard Version KIWA 18ATEX0013 X IECEx KIWA 18 0008X Declarations Mark Meter Options Standards Directives Marking Status Certificate Explosion...

Page 14: ...ipment depends not on the equipment itself but on operating conditions of the process uid gas owing through the equipment The equipment by itself does not generate heat Due to this reason the temperat...

Page 15: ...nsists of a biasing magnet and hermetically sealed reed switch which is insulated to prevent damage from mild shock and normal pipe vibration The contact rating of the switch is very low 0 5A An exter...

Page 16: ...t have a breaking capacity in accordance with the prospective short circuit current of the circuit to properly break the systems highest short circuit current In case device is mounted in an area wher...

Page 17: ...ically safe circuits An additional external connection facility for an equipotential bonding conductor is provided on the metallic enclosure The product should be installed by suitably trained personn...

Page 18: ...Section 1 13 Figure 1 5 Reed Switch Alarm UL Installation...

Page 19: ...tacts may be made to operate simultaneously For hazardous area applications Brooks can supply an approved Namur power supply amplifier relay unit to obtain an intrinsic safe current circuit Please ref...

Page 20: ...type of valve can cause pressure shocks which can damage the glass tube GT1600 Alarm Contact Bistabble Inductive Switches Meter Size 2 to 6 Application Electrical Equipment for use in Hazardous locat...

Page 21: ...Section 1 Figure 1 7 Dimensions and Specs Intrinsically Safe Switch Isolators 16...

Page 22: ...ged or missing parts Recommended Storage Practice If intermediate or long term storage of equipment is required it is recommended that the equipment be stored in accordance with the following a Within...

Page 23: ...recommended that the typical piping arrangement shown in Figure 2 1 be used when installing the meter This piping arrangement permits the meter to be isolated from the flow for servicing or cleaning...

Page 24: ...eference lines are not aligned loosen the screws securing the scale and move it until the marks are in alignment Then tighten the screws Operating Instructions After the flowmeter has been properly in...

Page 25: ...H IN V OUT 9 1 1 0 7 38 441 3 V IN H OUT 7 1 8 6 75 425 5 V IN H OUT 9 10 17 38 441 3 V IN V OUT Retro t only 4 GT1307 1307 16 94 430 2 H IN H OUT 7 8 3 94 100 0 H IN H OUT 9 1 4 0 72 120 0 V IN V OUT...

Page 26: ...Section 4 Overview 21...

Page 27: ...e float stops float and end fittings with a suitable solvent 6 Install the inlet float stop into the metering tube Refer to Figure 1 3 for the correct orientation of the float Slide the float into the...

Page 28: ...Section 5 General See Figures 5 1 and 5 2 and Table 5 1 for parts assembly drawings and parts list Figure 5 1 GT1600 Sizes 2 6 Parts Assembly Drawing Ref GT16XX001_1 23...

Page 29: ...Section 5 Figure 5 2 GT1600 Sizes 7 10 Parts Assembly Drawing Ref GT16XX002_1 24...

Page 30: ...14 TUBE SEAT GASKET PACKING 15 CENTERING RING TUBE GASKET SZ 2 6 16 SLEEVE 17 LABEL CLEAR SCALE 18 RESERVED FOR LABEL WHITE BACKING 20 CENTERING RING 21 SCREW CENTERING RING 22 WINDOW ASSEMBLY 23 SCR...

Page 31: ...n nearest to you START UP SERVICE AND IN SITU CALIBRATION Brooks Instrument can provide start up service prior to operation when required For some process applications where ISO 9001 Quality Certifica...

Reviews: