Section 1
Alarm Accessories
Remotely mounted, switch isolator/power supplies are required for inductive
alarms and recommended for reed switch alarms. One or two single-pole,
double-throw (SPDT) relays are available with either 110 or 220 AC volt units.
Optional Needle Valves
For flow rate control, needle valves may be integral to the inlet or outlet side
of the instrument. Note, solenoid valves should not be used because this
type of valve can cause pressure shocks which can damage the glass tube.
GT1600 Alarm Contact (Bistabble Induc
ti
ve Switches) Meter Size 2 to 6
Applica
ti
on
Electrical Equipment for use in Hazardous loca
ti
on
Area Classi
fi
ca
ti
on
FM: Class I, II, III, Div 1, Groups A, thru G, T6
ATEX : II 2 G
Protec
ti
on Technique
Intrinsic safety
Cer
tifi
cate
Model: RC10-14-N3 or RC15-14-N3
Installa
ti
on Notes:
P Fuchs
ATEX : PTB 99 ATEX 2128 X
FM Approvals : Control Drawing:116-
0165G
Refer to P Fuchs ATEX & FM Cer
tifi
cate for: Input parameters, Max Ambient
Temperature, Special condi
ti
ons for use.
14
15
Figure 1-6
Bistable Inductive Switches for GT1600
Table 1-6 GT1600 Alarm Contact Creed Switch - ATEX/IECEX
Summary of Contents for GT1600
Page 10: ...Section 1 Figure 1 4 Dimensions GT1600 Series See Dimensions Tables on following pages 5...
Page 18: ...Section 1 13 Figure 1 5 Reed Switch Alarm UL Installation...
Page 21: ...Section 1 Figure 1 7 Dimensions and Specs Intrinsically Safe Switch Isolators 16...
Page 26: ...Section 4 Overview 21...
Page 29: ...Section 5 Figure 5 2 GT1600 Sizes 7 10 Parts Assembly Drawing Ref GT16XX002_1 24...