Brooks Instrument Model 5866 Pressure Controller
1-8
Power Requirements
N.C. 3.5 watts; +15 Vdc (±5%) @ 35 mA, -15 Vdc (±5%) @ 180 mA
N.O. 10.5 watts, ±15 Vdc (±5%) @ 350 mA
Class III Equipment: The dc Mains input shall be supplied from a SELV
(Separated Extra-Low Voltage) source.
Output Signals
Standard: 0-5 Vdc min load resistance 1 k ohm
Optional: 0-10 Vdc min load resistance 2 k ohm, 0 or 4-20 mA into
maximum 500 ohm
5 Volt Reference Output
5 Volts ±0.2% min Load 1 k ohms.
Pressure Setpoint Signals
Standard: 0-5 Vdc input (impedance 1M ohm)
Optional: 0-10 Vdc input (impedance 1M ohm), 0 or 4-20 mA input
(impedance 250 ohm)
Remote Pressure Sensor Input
Standard: 0-5 Vdc input (impedance 1M ohm)
Optional: 0-10 Vdc input (impedance 1M ohm)
Dimensions
Refer to Figure 1-4
Standard: Normally Closed
Optional: Normally Open
Process Connections
Standard: 1/4" stainless steel compression fittings
Optional: 1/4" VCR
TM
, 1/4" VCO
TM
, 1/8" compression
Electrical Connection
15 pin D-Connector (DA-15P)
Environmental Conditions
Installation Category: “I”
Pollution Degree: 2
Humidity: 50-80% Relative Humidity
Meter Altitude: 6562 feet (2,000 meters)
For Indoor Use ONLY
Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage
Environmental Effects
EMC EffectsMeets the requirement of the EMC directive
(89/336/EEC) EN 61000-4-2 thru 4-8
PED
Sound Engineering Practice (SEP)
Area classifcation and certification
Area
Certified for use in hazardous areas in Europe
II 3 G EEx nA II T4
KEMA 03ATEX1532 X
Per EN 60079-15:2003
The modules shall be installed in a suitable enclosure providing a degree of
protection of at least IP54 according to EN 60529, taking into account the
environmental conditions under which the equipment will be used.
Summary of Contents for 5866
Page 20: ...3 3 Operation Figure 3 2 Proportional Control Figure 3 3 Integral Control ...
Page 21: ...Brooks Instrument Model 5866 Pressure Controller 3 4 Figure 3 4 P I Control ...
Page 23: ...Brooks Instrument Model 5866 Pressure Controller 4 2 ...
Page 32: ...5 9 Troubleshooting Figure 5 3 Valve Adjusting Spacer Locations ...
Page 34: ...5 11 Troubleshooting Figure 5 4 Valve Adjusting Spacer Locations Normally Open N O Valve ...
Page 43: ...Brooks Instrument Model 5866 Pressure Controller 6 6 ...
Page 45: ...Brooks Instrument Model 5866 Pressure Controller 7 2 Figure 7 1 Model 5866E Parts Drawing ...
Page 47: ...Brooks Instrument Model 5866 Pressure Controller 7 4 Figure 7 2 Model 5866M Parts Drawing ...
Page 48: ...7 5 Parts List Table 7 3 Model 5866M Parts List ...
Page 49: ...Brooks Instrument Model 5866 Pressure Controller 7 6 ...
Page 65: ......