(SDS) for the fluid(s) used in the instrument. Failure to provide this
information will delay processing of the instrument. Instrument must
have been purged in accordance with the following:
Transit Precautions
To safeguard against damage during transit, transport the device to
the installation site in the same container used for transportation
from the factory, if circumstances permit.
Removal from Storage
Upon removal of the device from storage, a visual inspection should
be conducted to verify its "as-received" condition. If the device has
been subject to storage conditions more than those recommended
(refer to "Recommended Storage Practice"), it should be subjected
to a pneumatic pressure test in accordance with applicable vessel
codes. To maintain a device’s ultra-clean integrity, this service
should be performed by the factory or one of the certified service
centers.
Gas Connections
Prior to installation, ensure that all piping is clean and free from
obstructions. Install piping in such a manner that permits easy
access to the device if removal becomes necessary.
In-Line Filter
It is recommended that an in-line filter be installed upstream from
the device to prevent the possibility of any foreign material entering
the flow sensor or control valve. The filtering element should be
replaced periodically or ultrasonically cleaned.
Mechanical Installation
Section 2 Installation
11
Summary of Contents for GP200 Series
Page 1: ...Installation Operation Manual GP200 Series Metal Sealed Pressure Based Mass Flow Controllers ...
Page 10: ...Table 1 3 Specifications for GP200 Series Section 1 Introduction 6 ...
Page 11: ...Section 1 Introduction 7 ...
Page 12: ...Figure 1 1 Dimensions of GP200 Series Downport Configurations Section 1 Introduction 8 ...
Page 13: ...Figure 1 2 Dimensions of GP200 Series VCR Configurations Section 1 Introduction 9 ...